Concrete heating mats of Hemstedt can be mould directly into foundations and floors.

Features and benefits

  • Usable as storage heating
  • 100 to 160 W/m² power
  • Can be laid in screed and concrete
  • Maintenance-free
  • Also suitable as wall heating
  • Sleeveless

Do you have any questions or like to place an order?

General questions
07135/98 98 0 or office@hemstedt.de

Question about our products
inquiries@hemstedt.de

Orders
orders@hemstedt.de

Use walls and floors as energy storage

The classic night storage heating is somewhat discredited. But in the context of the energy revolution and the increasing availability of solar or wind energy, the storage heaters are regaining importance. Because here, excess energy can be stored useful in the form of heat and reemitted over several hours, without the addition of more energy. 

Ideal for already existing real estates

Not every existing property can be transformed into a low-energy house in the course of restoration. But with the concrete heating mats of Hemstedt, cheap energy from overnight rates or excess energy from power spikes, for example generated by wind energy, can be stored and used. 

Save energy - conserve resources

So not only heating costs can be saved, it is also a meaningful contribution to the energy revolution. Because thanks to storage heaters, for example, wind energy can be stored in the early morning in the form of heat. When the electric supply networks are busy with the beginning of the day, energy for heating is no longer needed. 

Wise control and regulation

Hemstedt concrete heating mats can be used as storage heaters much better, if an intelligent control is used that controls all appliances in the household, including the storage heater and matches them if necessary with availability. Corresponding intelligent controls can be found here: controller and thermostats

Our products also run on fuel cell / hydrogen technology!
Made in Germany - since 1974
  • Underfloor heating is harmful to your health? Wrong!

    This prejudice is from the 1960ies and no longer correct.

    Quite the contrary!

    Here You get to know why!

  • Electric underfloor heating is expensive? Wrong!

    A comparison in terms of acquisition and consumption gives clarity.

  • Electric underfloor heating

    Pros and cons underfloor heating – Does it make sense?

  • Creative freedom and feel good architecture thanks to underfloor heating

    „Heat coming up from beneath as naturally as heat rises - there is no other ideal heat“ (Frank Lloyd Wright)

Specifications BH-IM CONCRETE HEATING MATS Item no. 31801

Nominal voltage 230 Volt
Output ca. 100/120/140/160/180/240 W/m²
Cold connection cable 1 x 4.00 m [1.00mm²]
Min. installation temperature 5°C
Max. temperature outer sheath 65°C
Min. bending radius 5 x dA
Resistance tolerance -5 % / +10 %
Cold/warm splice sleeveless, without shrinkable sleeve
Diameter ca. 7.5 mm
Insulation XLPE
Dlivery width 0.80 m
Calculation width 0.90 m

To top